AUD306.24

Milwaukee MC510 PRO Digital Redox ORP Controller

Add to Wishlist
Current Stock:
SKU: MC510
Range: +/- 1000 mV
Resolution: 1 mV
Accuracy: 5 mV

Description

The Milwaukee PRO digital Redox ORP controller automatically monitors and fine-tunes ORP levels. Just set your ORP parameters and let the Milwaukee ORP Controller do the rest.

The Milwaukee PRO digital ORP controller is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are aquariums, swimming pools and spas, and other water quality monitoring uses.

The Milwaukee PRO ORP controller offers:

Accuracy

The Milwaukee PRO ORP controller is accurate ±5 mV.

Automation

The controller provides a control range of ±1000 mV with a user selectable set point with a range of 0 - 600 mV and a visual "Power Activated" LED light.

Compatible dosing pump

Milwaukee includes a 12 VDC power plug socket compatible with Ozone Dosing units.

Easy installation

The ORP Controller comes with a complete mounting kit including a probe holder.

Design features

  • Fast easy to read current results with large digital LCD readout
  • Accurate to ±5 mV with the user selectable high/low set points
  • Gel-filled, double junction lab grade Platinum ORP electrode for low maintenance and high performance included
  • 6.5 feet probe cables for extra flexibility when testing
  • 12 VDC power supply, For local plug conversion, you will need to source an EU to AU plug converter. 

Care and Use 

Properly maintaining your ORP probe will give your fast, accurate results for longer.

Here are our top four tips. 

  1. Always store upright with the cap full of MA9015 Storage solution for BEST RESULTS.
  2. Clean your Tester regularly by soaking in MA9016 Cleaning Solution for about 20 minutes.
  3. If needed, clean the Platinum tip with very fine abrasive paper.
  4. After cleaning return the ORP probe sensor to the tank.

 

Thank you for considering Milwaukee to help you take your results to the next level.

Specifications

  • Range: ±1000 mV
  • Resolution: 1 mV
  • Accuracy: ±5 mV
  • Calibration: Factory checked
  • Set Point Range: 0 - 600 mV with alarm active when reading is higher or lower than set point
  • Dosing Contact: 1 power plug for O3 dosing
  • Electrode: Double Junction MA921B/2 Probe (included)
  • Environment: 0 - 50°C | 32 to 122°F; max RH 95%
  • Power Supply: 12 VDC adapter (included)
  • Power Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz
  • Dimensions: 5.8 x 3.2 x 1.3 inches
  • Weight: 6.3 ounces (meter only)